How to calculate thermal expansion
Expansion (in) = length (ft) × 12 × temperature change (°F) × coefficient
| Material | Coefficient |
|---|---|
| Copper | 9.5 × 10⁻⁶ in/in/°F |
| PEX | 72 × 10⁻⁶ in/in/°F |
| CPVC | 35 × 10⁻⁶ in/in/°F |
| PVC | 30 × 10⁻⁶ in/in/°F |
| Galvanized Steel | 6.5 × 10⁻⁶ in/in/°F |
| Stainless Steel | 9.6 × 10⁻⁶ in/in/°F |
Worked example
50 ft of PEX heated by 80°F grows 50 × 12 × 80 × 72 × 10⁻⁶ = 3.46 inches. The same run in copper grows 0.46 inches.
Leave room for expansion with loops, offsets or expansion joints on long hot-water runs, and don't anchor both ends of a straight run tight.
Questions
How much does PEX expand?
About 0.86 inches per 100 ft for every 10°F of temperature change (72 × 10⁻⁶ in/in/°F), roughly 7.6 times as much as copper.
Does cold water pipe need expansion room?
Usually not much, but hot water and recirculation lines do. Long runs of plastic pipe always need it.